Mobile HMI devices with functional safety
FAQ for Mobile HMI Devices
Please note: The FAQs below are intended as a general guide and provide initial assistance with frequently asked questions regarding the M2Smart® HMI system. The FAQs do not claim to be exhaustive! For the safe and correct use of the M2Smart® HMI system, it is essential to be familiar with and follow the Operating and Project Engineering Manual, as well as the warnings and safety instructions contained therein.
Questions about the M2Smart® HMI system
- M2Smart® HMI5 or M2Smart® HMI10 (mobile, battery-powered operator panel with emergency stop and enable button)
- M2Smart® Gateway i or M2Smart® Gateway o (link between the control panel and the safety PLC)
- Optional accessories
Yes, the NFC tag works even when attached to metal. With the M2Smart® HMI10, pairing via NFC tag is possible without any problems, even if the tag is attached to metal.
With the M2Smart® HMI5, due to the reading range, it is necessary to attach the NFC tag along with a spacer if it is positioned on metal. The spacer is supplied as standard when purchasing an M2Smart® Gateway.

Please note the following when pairing with the NFC tag:
- When aligning the NFC tag, ensure that it is positioned with the front facing.
- If the NFC tag is positioned on metal, ensure that the supplied spacer is used with the M2Smart® HMI5.
- The NFC tag must be held against the M2Smart® HMI until the notification “Connection is being established” is displayed.
The ACD WebAppService provides an API interface to integrate device functions and functions of the M2Smart® HMI system into a web application.
The App Guardian settings are an exception to this and are stored on the M2Smart® HMI device.
No, the password cannot currently be changed. You can find the default password in the latest version of the Operating and Project Engineering Manual.
This may be due to the previous connection. If the previous connection was not terminated correctly or other errors occurred in the meantime, these errors are stored on the M2Smart® Gateway and displayed the next time a connection is established. This process occurs regardless of whether the same M2Smart® HMI or a different one is used to re-establish the connection.
The default setting is 30 days, after which the error descriptions are automatically deleted. However, this period can be adjusted individually via the configuration file “HMIService.json” using the parameter “KeepLogForXDays”. Further information can be found in the Operating and Project Engineering Manual.
No, there is currently no Sistema library available. The safety data sheets can be found in the Operating and Project Engineering Manual.
The EPLAN data for the M2Smart® Gateway i and the M2Smart® Gateway o can be found on the following website under the heading “Portable Devices Retail / Logistics and Industrial electronics”: Downloads
Example circuits are available on the following website under the heading “Portable Devices Retail / Logistics and Industrial electronics”: Downloads
As soon as the battery is removed, the M2Smart® HMI system enters a safe state.
The fault reaction time is the maximum time required for the M2Smart® HMI system to enter a safe state following the occurrence of a fault. This can be configured by the customer and ranges from 225 to 1,000 milliseconds, depending on the setting. The default value is 300 ms.
The maximum discrepancy time is 10 ms.
The abbreviation PL stands for ‘Performance Level’. The Performance Level is a measure of the reliability of a technical safety function and indicates the probability of a dangerous failure. The Performance Level is classified from PLa (lowest reliability) to PLe (highest reliability). The Performance Level is defined in DIN EN ISO 13849-1. With the M2Smart® HMI system from ACD Elektronik, PLd can be achieved in accordance with DIN EN ISO 13849-1.
If the M2Smart® HMI system is in a safe state, all fail-safe outputs and the emergency stop LED are switched off. Further information on this can be found in the Operating and Project Engineering Manual.
No, the current safety concept of the M2Smart® HMI system does not allow for the individual definition of the safe state.
Yes, by actively disconnecting the connection via an enable button or code, the connection between the M2Smart® HMI operator terminal and the M2Smart® Gateway can be terminated without the M2Smart® HMI system entering the safe state. Further information on this can be found in the Operating and Project Engineering Manual.
No, the restricted operating area is not a safety function. Therefore, the safe state of the M2Smart® HMI system is not activated when the user is in the warning zone. However, the M2Smart® HMI control unit informs the user, both acoustically and via a haptic signal from a vibration motor, that they are in the warning zone.
A factory reset serves to reset all settings of the M2Smart® HMI as well as all apps and data. After a factory reset of the M2Smart® HMI, please note the following:
- All apps that were pre-installed on the M2Smart® HMI will be automatically reinstalled after the factory reset (e.g. ACD HMIConfig, ACD HMIService).
- To activate ACD HMIService, the ACD HMIConfig App must be launched once. After that, pairing with an M2Smart® Gateway is possible as usual.
- Any apps installed later may need to be reinstalled. The apps provided by ACD Elektronik for subsequent installation can be found in the same location as they were when the device was first shipped.
Questions about the M2Smart® HMI10
The NFC reading area on the M2Smart® HMI10 is located at the top left, directly next to the orange button. The area is also marked with an icon.


Questions about the M2Smart® HMI5
With a constant connection, the operating time of the M2Smart® HMI5 with a fully charged battery is approximately six hours at room temperature. This time depends on the screen sleep setting, the CPU load and the age of the battery.
The NFC reading area on the M2Smart® HMI5 is located in the upper section on the back of the device. To pair the device, the M2Smart® HMI5 must be held against the NFC tag.

It is possible to assign a static IP address. Details can be found in the Application Note.
Questions about the M2Smart® Gateway i or M2Smart® Gateway o
There are three safe outputs on the M2Smart® Gateways. One each for the emergency stop, the enable button and the connection indicator. All safe outputs are dual-channel.
Questions about the M2Smart® HMI Access Point
The connection to the M2Smart® HMI Access Point is only active as long as the connection to the M2Smart® Gateway is maintained. However, the M2Smart® HMI Access Point must always be switched on and broadcasting a network so that a connection can be established at any time.

Any further questions about the M2Smart® HMI system?
Was your question not answered, or do you need further support with commissioning the M2Smart® HMI system?
Please feel free to contact our Technical Consulting team:
Tel.: +49 7392 708-488
E-Mail: support.technik@acd-elektronik.de
Are you looking for further documentation?
Further documentation, such as the Operating and Project Engineering Manual and various application notes, is available to you after free registration on the customer portal.